1、Frequency band: 50 to 4000MHz
2、 Typical Gain: 20dB
3、OIP3: 32.0dBm
4、50 Ohm input and output impedance
5、Single, positive DC supply voltage
6、Temperature compensation
7、Industry standard SOT-89 package
| 
				 Parameter  | 
			
				 Specification  | 
			
				 Units  | 
		||||
| 
				 Min.  | 
			
				 Typ.  | 
			
				 Max.  | 
		||||
| 
				 Small Signal Gain  | 
			
				 900MHz 1900MHz 2400MHz  | 
			
				 
 
  | 
			
				 21.0 19.8 19.4  | 
			
				 
 
  | 
			
				 
 dB 
  | 
		|
| 
				 Output P1dB  | 
			
				 900MHz 1900MHz 2400MHz  | 
			
				 
 
 
  | 
			
				 20.5 20.8 19.8  | 
			
				 
 
 
  | 
			
				 
 dBm 
  | 
		|
| 
				 OIP3  | 
			
				 900MHz 1900MHz 2400MHz  | 
			
				 
  | 
			
				 33.5 32.0 31.7  | 
			
				 
 
 
  | 
			
				 
 dBm  | 
		|
| 
				 Input Return Loss  | 
			
				 900MHz 1900MHz 2400MHz  | 
			
				 
  | 
			
				 10 10 14  | 
			
				 
 
 
  | 
			
				 
 dB 
  | 
		|
| 
				 Output Return Loss  | 
			
				 900MHz 1900MHz 2400MHz  | 
			
				 
  | 
			
				 15 12 25  | 
			
				 
 
 
  | 
			
				 
 dB 
  | 
		|
| 
				 Reverse Isolation  | 
			
				 900MHz 1900MHz 2400MHz  | 
			
				 
  | 
			
				 27 27 27  | 
			
				 
 
 
  | 
			
				 
 dB 
  | 
		|
| 
				 Noise Figure  | 
			
				 
 
 
  | 
			
				 
 
  | 
			
				 4.5  | 
			
				 
 
  | 
			
				 dB  | 
		|
| 
				 Device Operating Voltage  | 
			
				 
  | 
			
				 +5.0  | 
			
				 
  | 
			
				 V  | 
		||
| 
				 Device Operating Current  | 
			
				 
  | 
			
				 87  | 
			
				 
  | 
			
				 mA  | 
		||